Electrolytic Cells for EPR
•Wilmad’s Electrolytic Cell Assemblies
•Components for Wilmad’s Electrolytic Cell Assembly
•Electrode Reference Solutions and Cleaners
Wilmad’s Electrolytic Cell Assemblies
Study electrolytically generated radicals in aqueous solutions.
Avoid alkali metal reductions, the associated sample sensitivity to air or moisture and background signals! Never deal with a high vacuum apparatus again!
The electrochemical or coulometric generation of radicals in aqueous media has been employed successfully for years. It’s ideal for biological samples because of the control afforded by voltaic methods. Just connect Wilmad’s Electrolytic Cell to a potentiostat.
Controlled oxidation-reduction reactions can be carried out right in the EPR cavity! A complete cell includes two Calomel Reference Electrodes, a pair of Platinum Electrodes, and a gas bubbler for deoxygenation. Wilmad provides the Electrolytic Cell Assembly as a complete unit with CFQ or Suprasil®Flat Cell, or you can order components separately. Electrolytic cells are available for the TE102or TE011cavities of all spectrometers.
Components:
Flat Electrolytic Cells have two
The Gas Bubbler Assembly is a three-piece Pyrex chamber which holds part of your sample. It has three
Platinum Electrodes are prepared using 0.016″ (0.4mm) diameter wire. The upper electrode, WG-810-C, uses 8″ (203mm) of platinum and acts as the working electrode in oxidation reactions. The lower electrode, WG-810-D, has only 2″ (50mm) of platinum and acts as the auxiliary electrode in oxidation reactions. If you add a few drops of mercury to the cell, the lower electrode can be used as the working cathode in reduction reactions. Each Platinum Electrode incorporates a Pt-to-W weld. The tungsten (W) external wire lets you quickly clip your potentiostat leads to the electrode.
Electrolysis Limits in Water (vs. Saturated Calomel Electrode)
Calomel Electrodes are included in two lengths, one 13″ (330mm) and the other 83/4” (222mm). Connect your potentiostat to the half cell at a tungsten wire that penetrates the electrode wall. Add mercury in the outer chamber to a height that makes contact with the tungsten lead. Each electrode provided with a stopper. Not supplied with mercury. Electrolytes sold separately.
Wilmad Electrolytic Cell Assemblies
TIP: An electrolytic cell designed by Prof. Robert Allendorfer of SUNY, Buffalo and sold by Bruker Instruments offers improved sensitivity using a cylindrical TM110cavity. Its use is recommended when sample sensitivity is low.
Remember: Wilmad uses “-Q” to designate versions using Suprasil in the critical portions of the cell. All other cells are prepared from Clear Fused Quartz (CFQ).
Components for Wilmad’s Electrolytic Cell Assembly
Please note: Items marked “CALL” are custom manufactured – please contact Customer Service for single piece or lot pricing.
Flat Electrolytic Cells
These cells have two
Gas Bubbler Assembly
A three-piece Pyrex chamber which holds part of your sample. It has three
Platinum Electrodes
Prepared using 0.016″ (0.4mm) diameter wire. The upper electrode, WG-810-C, uses 8″ (203mm) of platinum and acts as the working electrode in oxidation reactions while the lower electrode, WG-810-D, has only 2″ (50mm) of platinum and acts as the auxiliary electrode. Adding a few drops of mercury to the cell allows the lower electrode to function as the working cathode in reduction reactions. Each Platinum Electrode incorporates a Pt-to-W weld. The tungsten (W) external wire lets you quickly clip your potentiostat leads to the electrode.
Calomel Electrodes
Supplied in two lengths, one 13″ (330mm) and the other 83/4” (222mm). Connect your potentiostat to the half cell at a tungsten wire that penetrates the electrode wall. Add mercury in the outer chamber to a height that makes contact with the tungsten lead. Each electrode is provided with a stopper.
Remember: Like many Quartz products for EPR, Electrolytic Cell components can often be repaired for costs that are less than new components. Contact Customer Service to ask about this service.
Electrode Reference Solutions and Cleaners
Calomel Reference Electrodes utilize a 3M potassium Chloride (KCl) solution saturated with Silver Chloride (AgCl). Use it to fill or replace reference solution in any pH or other electrode which incorporates a Calomel Reference.
In addition, we provide cleaning solutions which can be used to remove specific surface contaminants from your reference electrode junction.
Miscellaneous EPR Supplies •Sample Handling Accessories •EPR/NMR Tube Caps •NMR/EPR Tube Racks •NMR/ EPR Tube…
Variable Temperature Accessories Replacement Parts for VT Systems Need a replacement component for your variable…
EPR電子順磁共振儀耗材 Dewar Flasks Cold-Finger Dewars•Large Nitrogen Dewar Flasks •Liquid Nitrogen Dewar Flask Dewar Flasks provide…
EPR電子順磁共振儀耗材 Dewar Inserts Dewar Inserts Standard VT Dewar Inserts Simple Dewar Inserts JEOL Dewar Inserts…
EPR Cells • Standard Aqueous Cells • Special Aqueous Cells with Hexagonal Fill Tubes •…
EPR Sample Tubes - Quartz (CFQ) Important Note: Product numbers that include "PQ" belong to…